Sign In | Join Free | My chinaqualitycrafts.com |
|
Certification : ISO, CE
Supply Ability : 100/Year
Payment Terms : L/C, T/T, D/P
Brand Name : GENY
Model Number : YCS-101
Place of Origin : CHINA
Model NO. : YCS-101
Display : Digital
Installation : Direct Connected
Usage : Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment : Single-phase
Theory : Electronic Meter
Power Meter Connection : Terminal
Measured Signal : Pulse Peak
Type : Energy Meter
Customized : Customized
Trademark : GENY
Transport Package : Plywood Case
Specification : 0.672CBM
Origin : China
HS Code : 9030849000
Port : Guangzhou, China
YCS-101Single Phase Power Source
Application Conditions and Requirements | |||||
Environment | Power Requirement | Safety | |||
Operation Temperature | Humidity | Altitude | Voltage Supply | IP Class | Conformity |
-10ºC--+40ºC | 35%--85% | <2500m | 3x220/380V±10%(or customized) | IP30 | CE conform |
50/60Hz±2Hz | |||||
Type | YCS-101-250 | YCS-101-600 | YCS-101-1200 | YCS-101-2500 | |
Voltage | |||||
Test voltage output(Phase-Neutral) | 24V-300 V or customized | ||||
Power of the voltage output | Max.100VA | Max.250VA | Max.500VA | Max.1000VA | |
Resolution | Better than 0.01% of full scale value of range | ||||
Setting accuracy | Better than 0.05% at the final range value | ||||
Stability | Better than 0.005%/h (integration time 150 s) | ||||
Load regulation from 0-max.load | Better than 0.01% | ||||
Distortion factor | Better than 0.3% for linear resistance load | ||||
Harmonics | 2nd-41st free programmable | ||||
Current | |||||
Test current output | 1mA-120A/200A | ||||
Power of the current output | Max.250VA | Max.500VA | Max.1000VA | Max.2000VA | |
Resolution | Better than 0.01% of full scale value of range | ||||
Setting accuracy | Better than 0.05% at the final range value | ||||
Stability | Better than 0.005%/h(integration time 150 s) | ||||
Load regulation from 0-max.load | Better than 0.01% | ||||
Distortion factor | Better than 0.3% for linear resistance load | ||||
Harmonics | 2nd-41st free programmable | ||||
Phase angle | |||||
Range | 0-360° | ||||
Resolution | 0.01° | ||||
Setting accuracy | 0.1° | ||||
Frequency | |||||
Range | 45Hz-65Hz | ||||
Resolution | 0.01Hz | ||||
Error display | |||||
Type of error display | Red LED | ||||
Resolution of the error displays | 8 digits |