Sign In | Join Free | My chinaqualitycrafts.com |
|
Brand Name : GENY
Model Number : YC99T
Certification : ISO, CE
Place of Origin : China
MOQ : 1
Price : negotiate rates
Payment Terms : T/T,L/C,D/P,T/T
Supply Ability : 10 pcs/ 1 months
Delivery Time : 6~8weeks
Packaging Details : Plywood cases
Model : YC99T
Accuracy Class : 0.05%
Max Voltage : 456V (P-N)
Max Current : 120A
Test current output : 3*(1mA-120A)
Test voltage output : 3*(0V-450V)
GENY YC99T-5C | GENY YC99T-3C | ||||||||||
General | |||||||||||
Power supply | 220V±15% or 110V±15% | 220V±15% or 110V±15% | |||||||||
Power consumption | 60VA~1600VA | 50VA~1000VA | |||||||||
Temperature range, operation | 20℃~30℃, | 20℃~30℃, | |||||||||
Temperature range, storage | -20℃~50℃ | -20℃~50℃ | |||||||||
Relative humidity (not condensing) | ≤85% | ≤85% | |||||||||
Dimensions (DxWxH) | 600mm× 440mm× 264mm | 600mm× 440mm× 176mm | |||||||||
Weight | 45kg | 28kg | |||||||||
Safety | |||||||||||
IP class according to DIN EN 60529 | |||||||||||
Declaration of conformity | |||||||||||
Protection class according to DIN EN 61140 | |||||||||||
Source | |||||||||||
Voltage min. max. | 0-456V(Phase to neutral) | 0-792V(Phase to neutral) | |||||||||
Voltage range(s) | 57.7V,100V,220V,380V | 57.7V,100V,220V,380V,660V | |||||||||
Voltage max. output power | 20VA per phase | 20VA per phase | |||||||||
Voltage distortion | ≤0.2%(None capacity load) | ≤0.2%(None capacity load) | |||||||||
Voltage resolution | 0.01% of range | 0.01% of range | |||||||||
Voltage accuracy | 0.05% of range | 0.05% of range | |||||||||
Voltage stability | 0.01%/2min | 0.01%/2min | |||||||||
Voltage load dependence | Capacity/Inductance/Resistance | ||||||||||
Current min. max. | 0-120A | 0-60A | |||||||||
Current range(s) | 50mA,200mA,1A,5A,20A,100A | 50mA,200mA,1A,5A,16.67A,50A | |||||||||
Current max. voltage per range | 1V at 100A | 1V at 60A | |||||||||
Current max. output power | 120VA | 60VA | |||||||||
Current distortion | ≤0.2%(None capacity load) | ≤0.2%(None capacity load) | |||||||||
Current setting resolution | 0.01% of range | 0.01% of range | |||||||||
Current accuracy | 0.05% of range | 0.05% of range | |||||||||
Current stability | 0.01%/2min | 0.01%/2min | |||||||||
Current long term stability | 0.05% of range | 0.05% of range | |||||||||
Current load dependence | Resistance | Resistance | |||||||||
Frequency range | 40Hz ~70Hz | 40Hz ~70Hz | |||||||||
Frequency accuracy | 0.002 Hz | 0.002 Hz | |||||||||
Frequency setting accuracy | 0.001Hz | 0.001Hz | |||||||||
Phase angle setting range | 0~360° | 0~360° | |||||||||
Phase angle setting resolution | 0.01° | 0.01° | |||||||||
Phase angle accuracy | 0.05° | 0.05° | |||||||||
Phase angle stability | 0.05° | 0.05° |
*If you want to know more please check our official website:http://www.genymetertestequipment.com/
![]() |
Portable Energy Meter Test Bench Images |